    Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
    Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
    SM-602 programmable safety controller

    As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

    (1) Redundancy

    (2) Difference

    (3) Self-detection


       How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


    SM-602 programmable safety controller

    1720164449995785.png

    Is a configurable safety controller, which supports the input of various safety product components.

    Maximum support for 6 sets of dual-loop inputs.

    2-way safety relay output

    4-channel semiconductor safety output, expandable output module

    Modbus protocol communicationInput and output fault indicator light

    Safety certification: PL e, Cat: 4


    Product selection

    product name

    Type number

    Safe input

    Output

    Brand

    Safety controller

    SM-602

    6CH

    2NO+4SO

    LHS

    explain

    Up to 6 sets of dual-channel safety products can be entered.

    Safety grating, emergency stop, safety door lock, reset, etc.

    Official website programming software download connection: http://lhsafety.com.cn/showinfo-257-118-0.html








    safety performance

    ? Performance level (PL): PL e

    ? Security category (Cat.): Cat.4

    ? Mission time (TM): 20 years

    ? Diagnostic coverage (DC/DC avg): 99%

    ? Safety Integrity Level (SIL): SIL3

    ? Hardware Fault Margin (HFT): 1

    ? Safe Failure Score (SFF): 99%

    ? Probability of dangerous failure (PFH d): 1.78E-9/h

    ? Stop Category: 0/1

    Complies with standard EN ISO13849

    Complies with standard EN ISO13849

    Complies with standard EN ISO13849

    Complies with standard EN ISO13849

    Conforms to standards IEC61508, IEC62061

    Conforms to standards IEC61508, IEC62061

    Conforms to standards IEC61508, IEC62061

    Conforms to standards IEC61508, IEC62061

    Complies with standard EN 60204-1


    Main technical parameters

    Power supply 

    characteristics

    ·Power supply voltage: 24VDC

    ·Voltage range: 20~30VDC

    ·Current loss: ≤110mA(24VDC)

    Input characteristics

    ·Input current: ≤10mA(24VDC)

    ·Conductor resistance: ≤15Ω

    ·Input equipment: emergency stop button, safety door, two-hand button safety light curtain, magnetic safety switch, etc.

    ·Input channel: 6

    Relay output 

    characteristics

    ·Number of contacts: 2NO (safety output)

    ·Contact material: AgSnO2

    ·Contact fuse protection: 10A is fast, 6A is slow.

    ·Switching capacity: 5A/230VAC;; 5A/24VDC

    Semiconductor output characteristics

    ·Number of contacts: 4SO (safety output)

    ·Contact fuse protection: 10A is fast, 6A is slow.

    ·Switching capacity: 2A/24VDC

    Time characteristic

    ·Suction buffer time: ≤100ms

    ·Release buffer time: ≤30ms

    ·Recovery time:

             Emergency stop operation: ≤30ms

             Power failure: ≤1000ms

    ·Recovery time:

             Emergency stop operation: ≤30ms

             Power failure: ≤100ms

    ·Short-term power interruption: 20ms

    Communication 

    characteristics

    ·Baud rate: 38.4kbps (fixed)

    ·Communication length: ≤1000m

    ·Networking capacity: ≤10 units


    Environmental characteristic parameters

    ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

    ·Vibration frequency: 10Hz~55Hz

    ·Vibration amplitude: 0.35mm

    ·Service temperature: -20℃~+60℃

    ·Storage temperature: -40℃~+85℃

    ·Relative humidity: 10%~90%

    ·Overvoltage grade: Ⅲ

    ·Pollution level: 2

    ·Altitude: ≤2000m

    ·Rated isolation voltage: 250VAC.

    ·Rated impulse voltage: 6000V(1.2/50us)

    ·Insulation strength: 1500VAC, 1min.

    ·Electrical clearance and creepage distance: in accordance with EN60947-1.

    1666333314320610.png


    Functional application parameters

    functional block diagram

    Typical application

    圖片3.png

    圖片4.png


    Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

    Input element: CH4 (emergency stop button); CH5 (emergency stop button); CH6 (reset button)

    Control logic: CH1&CH2CH4&CH5

    Reset mode: manual reset output delay: 0s.

    Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


    Wiring diagram

    Power Supply 

    1.png

    correspondence

    1655948458157829.png

    input

    3.png4.png5.png
    6.png7.png
    9.png10.png

    reset

    11.png12.png

    feedback

    13.png14.png

    output

    15.png16.png17.png


    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh
  • 主站蜘蛛池模板: 久久狠狠一本精品综合网| 亚洲色一区二区三区四区| 熟妇人妻久久春色视频网| 无码不卡黑人与日本人| 国产成人精品午夜二三区波多野| 无码日韩精品一区二区人妻| 国产av不卡一区二区| 九九电影网午夜理论片| 国产成人精品亚洲精品日日| 日韩一二三无码专区| 潮喷无码正在播放| 亚洲熟妇自偷自拍另类| 国产精品午夜电影| 一本色道久久88| 亚洲精品另类| 国产超碰人人做人人爱ⅴa| 青青操视频免费观看| 久久精品日日躁夜夜躁| 中文字幕久久久久人妻中出| 精品欧美h无遮挡在线看中文| 国产在线观看91精品亚瑟| 久久月本道色综合久久| 国产午夜福利精品久久2021 | 高清精品视频一区二区三区 | 亚洲中文字幕无码卡通动漫野外| 国产精品久久久久尤物| 国产精欧美一区二区三区| 韩国理伦片一区二区三区在线播放 | 国产在线一二三区| 婷婷色爱区综合五月激情| 97超碰国产精品最新| 人妻久久久一区二区三区| 日韩一区二区三区不卡片| 日本免费更新一二三区不卡| 中国黄色一级视频| 免费无码专区在线视频| 亚洲欧美不卡高清在线观看 | 国产欧美久久久精品影院| 国产精品大白天新婚身材| 久久久欧美精品激情| 亚洲精品日产精品乱码不卡|