    LMC3-50 series RFID safety door switch

    1706678051308494.pngimage.png

    With detection confidentiality (unique code can be provided)

    ?Strong anti-interference, safety and reliability.

    ?Safety level PLe can be achieved by using safe dual-channel output technology.

    ?Effectively prevent false positives or false negatives, or artificial abnormal triggers.

    ?Can be used with the safety door.


    395181ccb7a771e30162f6415dc922a.png

    Ordering information

    86b9d0315b563dc534da6381bf695f3.png

    Switch model

    Specification

    Output method

    Encoding method

    LMC3-50-40SNT/5M


    4-core direct wiring with dual output
    5M cable


    NPN

    Universal encoding

    LMC3-50-40SN1/5M

    Unique encoding

    LMC3-50-40SPT/5M

    4-core direct wiring with dual output
    5M cable


    PNP

    Universal encoding

    LMC3-50-40SP1/5M

    Unique encoding

    LMC3-50-60JNT/5M

    6-core direct wiring with dual output and cascading 5M cable

    NPN

    Universal encoding

    LMC3-50-60JN1/5M

    Unique encoding

    LMC3-50-60JPT/5M

    6-core direct wiring with dual output and cascading 5M cable

    PNP

    Universal encoding

    LMC3-50-60JP1/5M

    Unique encoding

    395181ccb7a771e30162f6415dc922a.png

    Model Description


    395181ccb7a771e30162f6415dc922a.png

    Technical parameter

    Safty standard

    Mean Time to Dangerous Failure (MTTFd) (years)

    ISO13849-11EC/EN60947-5-1IEC/EN60947-5-3

    ≥30 years

    Safety classification

    Class 4 switch according to IS0 13849-1/suitable for PLe/PL

    Certification

    CE

    Horizontal working distance

    Conduction, min:10mm

    Vertical working distance

    Conduction, min:8mm

    Operating voltage

    24V DC±15%

    Operating current

    150mA

    Response time

    60ms

    The protection grades

    IP65, IP67 (customized)

    Operating frequency

    lHZ

    Working temperature

    -10~+55℃

    Relative humidity

    5%~95%

    Material

    Flame-retardant thermoplastic


    395181ccb7a771e30162f6415dc922a.png

    Shape and installation dimensions

    尺寸圖.pngLMC3-50.png


    395181ccb7a771e30162f6415dc922a.png

    Approach pattern of LMC3-50 switch

    1706679390304986.png1706679459242220.png


    395181ccb7a771e30162f6415dc922a.pngLMC3-50 switch induction distance


    Misalignment deviation

    breakover

    disconnect

    Alignment signal

    Horizontal alignment

    The deviation is within 4 mm in the X direction.Y direction induction 0~10mmY direction induction distance > 25mmLMC3-50.png
    The deviation is > 5mm and < -5mm in the x direction.Not recommended

    Vertical alignment

    The deviation is within 4mm of soil in X direction.Z direction induction distance 0~8mmZ direction induction distance > 23mmLMC3-510.png
    The deviation is > 5mm and < -5mm in the x direction.Not recommended


    395181ccb7a771e30162f6415dc922a.png

    Hookup

    Two-way output with cascade connection diagram

    serial number

    Signal definition

    colour

    explain

    1706680404188780.png

    1

    24V

    palm

    Power supply positive

    2

    0V

    blue

    Negative power supply

    3

    output1

    black

    Safety output 1

    4

    output2

    white

    Safety output 2

    5

    input1

    green

    Cascade input 1

    6

    input2

    yellow

    Cascade input 2


    395181ccb7a771e30162f6415dc922a.pngLegend of connection between RFID switch and safety relay module (dual output)


    接線圖.png



    395181ccb7a771e30162f6415dc922a.png

    RFID switch approach pattern

    Led display

    Signal state

    State description

    input

    output

    The red light is always on.

    Yes/No.

    break

    No actuator or incomplete alignment (universal coding)

    The red light is on for 1 second and then flashes twice (alternately).

    Yes/No.

    break

    No actuator or incomplete alignment (unique code)

    Red light flashing at 4Hz

    effective

    break

    Output overload

    Green light flashes at 1Hz.

    be invalid

    break

    No input signal (dual output is not applicable)

    The green light is always on

    effective

    through

    Induction is normal

    Alternate flashing of traffic lights

    effective

    break

    Label is not registered.


    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh
  • 主站蜘蛛池模板: 黑人巨大精品欧美视频一区 | 国语自产偷拍在线观看| 中文字幕久久久久久久系列| 精品国产aⅴ无码一区二区| 精品熟女少妇免费久久| 午夜精品久久久久久久2023| 性夜久久一区国产9人妻| 国产毛多水多高潮高清| 午夜国产理论大片高清| 欧美a级在线现免费观看| 色悠久久久久久久综合网伊人| 国产香蕉尹人综合在线观看| 国产一本一道久久香蕉| 亚洲国产精品一区二区成人片不卡 | 亚洲区欧美区| 亚洲愉拍自拍欧美精品| 国产精品午夜电影| 色网站在线视频| 亚洲欧洲∨国产一区二区三区| 狠狠亚洲色一日本高清色| 色综合天天综合网中文伊| 少妇被粗大的猛烈进出免费视频| 无码日韩av一区二区三区| 久久青草精品欧美日韩精品| 亚洲色欲色欲大片www无码 | 久久天天拍天天爱天天躁| 中文无码制服丝袜人妻av| 2021在线精品自偷自拍无码| 五月天久久综合国产一区二区| 无码AV一区在线观看免费| 成人欧美一区二区三区在线观看| 啪啪视频一区二区三区入囗| 午夜亚洲福利在线老司机| 亚洲国产午夜精品理论片妓女| 依依成人影视国产精品| 国产精品亚洲一区二区三区喷水| 国产高清在线男人的天堂| 国产成人高清精品亚洲| 国产精品午夜福利片国产| 少妇人妻在线视频| 超碰aⅴ人人做人人爽|