    Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
    Position首頁 > Home > Industrial Safety Products > Safety interlock switch > RFID Electromagnetic Locking Safety Door Switch
    D3SL-T/RFID electromagnetic locking type
    1.png

    ·Electromagnetic force locking 500N

    ·Adopt a small plane "electromagnetic" locking structure.

    ·Support 16 to 20 cascaded connections.

    ·Design of permanent magnet in matcher

    ·Small body, simple installation

    ·Full-angle eye-catching indicator light

    ·No abrasive powder will be produced.

    ·IP65/IP67 protection


    D3SL-T/RFID Series Selection Table

    Locking mode

    deploy

    model

    Output mode

    coded system

    Electromagnetic locking

    normalized form

    D3SL-T-DB-N2

    NPN

    universal coding

    D3SL-T-DB-N1

    NPN

    Unique coding

    D3SL-T-DB-P2

    PNP

    universal coding

    D3SL-T-DB-P1

    PNP

    Unique coding

    Advanced type

    D3SL-T-DG-N2

    NPN

    universal coding

    D3SL-T-DG-N1

    NPN

    Unique coding

    D3SL-T-DG-P2

    PNP

    universal coding

    D3SL-T-DG-P1

    PNP

    Unique coding


    Technical parameters of D3SL-T/RFID

    type

    Hinged door

    small-sized

    M12 connector

    normalized form

    High functional type

    working distance

    Sao(off-0n)

    4mm

    Sar(on-0ff)

    4mm

    Response time

    Lock → release

    155ms

    Release → lock

    155ms

    Detection → Non-detection

    20ms+2ms* (Number of cascaded connections -1)

    Non-detection → detection

    300ms+25ms* (Number of cascaded units -1)

    Control output

    (OSSD output)

    Output mode

    Transistor output "2

    Maximum load current

    150mA

    Residual voltage (on)

    Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

    OFF voltage

    Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

    leakage current

    Up to 0.5mA

    Maximum load capacity

    0.8uF

    Load connection resistance

    Max. 2.5 Euro

    AUX output

    (Non-safety system output)

    Output mode

    Transistor output

    Maximum load current

    50mA

    Residual voltage (ON)

    Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

    external input

    (Short-circuit current)

    Safety input

    About 1.5 max 2

    Locking control input OSSD action switching input

    About 2.5 mA

    Reset /EDM input

    About 5mA (high functional type only)

    EDM select input

    About 2.5 mA (high functional type only)

    Power Supply 

    Power supply voltage

    24 VDC 10% including ripple (P-P)10% Class2

    consumed power

    <5W

    protective circuit

    Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

    Environmental resistance

    Enclosure protection grade

    IP65/67(IEC60529)

    Operating ambient temperature

    20 degrees below zero to 55 degrees without freezing.

    Storage ambient temperature

    25 degrees below zero to 70 degrees without freezing.

    Using ambient humidity

    5% to 95%RH

    Storage environment humidity

    5% to 95%RH

    Vibration resistance

    10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

    Applicable standards

    ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


    Model description of safety switch

     1728548977520914.png 



    hookup

    Standard type (NPN, cascade)

    Standard (PNP, cascade)

    1719978292858022.png

    Standard type (NPN, cascade)

    1719978426648983.png

    Standard (PNP, cascade)

    1719978725470017.png

    Functional (NPN, cascade)

    Functional (PNP, cascade)

    1719979076106539.png

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    "1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

    S: reset switch

    "Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

    "1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    High functional type (NPN, cascade)

    1719979521976024.png

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

    3. EDM only: Turn off the EDM selection (chalk line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    Functional (PNP, cascade)

    1719979875434469.png

    Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

    S: reset switch

    Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

    *1. Make ?EDM and reset: wire as shown in the figure.

    2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

    3. EDM only: Turn off the EDM selection (chalk line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch


    Indication of indicator light

    1719983442751425.png


    Product ruler diagram

    1719983681983392.png


    Selection Method of Safety Switch D3SL-T/RFID Series

    1728618489514684.png



    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh
  • 主站蜘蛛池模板: 国产偷国产偷亚洲清高APP| 天天在线看无码AV片| 久久精品国产福利亚洲av| 久热天堂在线视频精品伊人| 亚洲精品一区二区三区福利| 在线播放免费人成毛片| 中文字幕日韩区二区三区| 国产色在线 | 日韩| 八个少妇沟厕小便漂亮各种大屁股| 无码午夜福利片| 午夜福利视频极品国产83| 91久久精品国产性色也| 2021最新国产在线人成| 亚洲熟女乱色一区二区三区| 蜜桃一区二区三区在线看| 99国产精品一区二区蜜臀| 亚洲国产精品一区二区第一页| 国产精品亚洲一区二区三区喷水| 日韩av一区二区精品不卡| 极品尤物被啪到呻吟喷水| 亚洲成av人在线观看无堂无码| 国产成人一区二区| 久久99热只有频精品6国语| 蜜桃一区二区三区免费看| 精品视频一区二区| 777亚洲精品乱码久久久久久| 久久综合久久香蕉网欧美| 亚洲www永久成人网站| av东京热无码专区| 久久九九精品99国产精品| 欧美19综合中文字幕| 蜜臀98精品国产免费观看| 自偷自拍亚洲综合精品| 亚洲 国产 韩国 欧美 在线 | 成人免费看www网址入口| 最新av中文字幕无码专区| 国产精品高潮呻吟久久影视a片| 色偷偷亚洲女人天堂观看| 亚洲色一区二区三区四区| 欧美无遮挡国产欧美另类| 亚洲国产一区在线二区三区|